The fixed‑lead precision current transformer features pre‑installed rigid leads for secure mounting and high vibration resistance. Combined with a high‑accuracy core and low phase‑error design, it maintains excellent measurement stability across wide temperature and frequency ranges, making it suitable for energy metering, industrial control, and precision laboratory systems.
| Fixed Lead — Precision Current Transformer | |||||
| ZH-GTA30L Series Precision Current Transformers | |||||
| GTA30L1.0 | GTA30L2.0 | Unit | |||
| Rated Input | 10 | 20 | A(AC) | ||
| Rated Output | 10 | 10 | mA(AC) | ||
| Ratio | 1000:01:00 | 2000:01:00 | Ratio | ||
| Phase Difference | ≤ 10 ' (RL=20Ω) | ≤5 ' (RL=20Ω) | Min | ||
| Linear Range | 0-60 (RL=20Ω) | 0-110 (RL=20Ω) | A(AC) | ||
| 0-50 (RL=50Ω) | 0-90 (RL=50Ω) | A(AC) | |||
| Linearity Degree | 0.20% | 0.10% | % | ||
| DC Resistance | 49±6Ω | 150±15Ω | Ω | ||
| Net weight | 28 | 28.9 | g | ||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-VO Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40°C to +70°C Sealing Material: Epoxy Resin Installation Method: Primary busbar through-hole, secondary lead output |
|||||
| Fixed Lead — Precision Current Transformer | |||||
| ZH-GTA27L Series Precision Current Transformers | |||||
| GTA21L | Unit | ||||
| Rated Input | 60 | A(AC) | |||
| Rated Output | 30 | mA(AC) | |||
| Ratio | 83.3340277778 | Ratio | |||
| Phase Difference | ≤5 ' (RL=20Ω) | Min | |||
| Linear Range | 0-80 (RL=20Ω) | A(AC) | |||
| 0-70 (RL=50Ω) | A(AC) | ||||
| Linearity Degree | 0.001 | % | |||
| DC Resistance | 148±20Ω | Ω | |||
| Net weight | 30 | g | |||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-VO Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40°C to +70°C Sealing Material: Epoxy Resin Installation Method: Primary busbar through-hole, secondary lead output |
|||||
| Fixed Lead — Precision Current Transformer | |||||
| ZH-GTA32L Series Precision Current Transformers | |||||
| GTA32L1.0 | GTA32L2.0 | GTA32L3.0 | Unit | ||
| Rated Input | 50 | 100 | 100 | A(AC) | |
| Rated Output | 50 | 50 | 33.3 | mA(AC) | |
| Ratio | 1000:01:00 | 2000:01:00 | 3000:01:00 | Ratio | |
| Phase Difference | ≤5 ' (RL=10Ω) | ≤5 ' (RL=10Ω) | ≤5 ' (RL=10Ω) | Min | |
| Linear Range | 0-100 (RL=10Ω) | 0-200 (RL=10Ω) | 0-190 (RL=10Ω) | A(AC) | |
| 0-70 (RL=30Ω) | 0-150 (RL=50Ω) | 0-150 (RL=50Ω) | A(AC) | ||
| Linearity Degree | 0.10% | 0.10% | 0.10% | % | |
| DC Resistance | 38±6Ω | 77±10Ω | 166±20Ω | Ω | |
| Net weight | 38.3 | 42 | 42.6 | g | |
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-VO Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy Resin Installation Method: Primary busbar through-hole, secondary lead output |
|||||
| Fixed Lead — Precision Current Transformer | |||||
| ZH-GTA27L Series Precision Current Transformers | |||||
| GTA27L1.0 | GTA27L2.0 | Unit | |||
| Rated Input | 100 | 200 | A(AC) | ||
| Rated Output | 100 | 100 | mA(AC) | ||
| Ratio | 1000:01:00 | 2000:01:00 | Ratio | ||
| Phase Difference | ≤ 50 ' (RL=10Ω) | ≤ 30 ' (RL=10Ω) | Min | ||
| Linear Range | 0-300 (RL=10Ω) | 0-1000 (RL=10Ω) | A(AC) | ||
| Linearity Degree | 0.50% | 0.50% | % | ||
| DC Resistance | 32±6Ω | 60±10Ω | Ω | ||
| Net weight | 82.7 | 89 | g | ||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary lead output |
|||||
| Fixed Lead — Precision Current Transformer | |||||
| ZH-GTA35L Series Precision Current Transformers | |||||
| GTA35L2.0 | GTA35L3.0 | GTA35L4.0 | Unit | ||
| Rated Input | 200 | 300 | 400 | A(AC) | |
| Rated Output | 100 | 100 | 100 | mA(AC) | |
| Ratio | 2000:01:00 | 3000:01:00 | 4000:01:00 | Ratio | |
| Phase Difference | ≤5 ' (RL=10Ω) | ≤5 ' (RL=10Ω) | ≤5 ' (RL=10Ω) | Min | |
| Linear Range | 0-240 (RL=10Ω) | 0-360 (RL=10Ω) | 0-480 (RL=10Ω) | A(AC) | |
| Linearity Degree | 0.10% | 0.10% | 0.10% | % | |
| DC Resistance | 55±10Ω | 87±10Ω | 92±15Ω | Ω | |
| Net weight | 98.5 | 100 | 103 | g | |
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-VO Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40°C to +70°C Sealing Material: Epoxy Resin Installation Method: Primary busbar through-hole, secondary lead output |
|||||
| Fixed Lead — Precision Current Transformer | |||||
| ZH-GTA09L Series Precision Current Transformers |
|||||
| GTA09L1.0 | GTA09L2.0 | Unit | |||
| Rated Input | 100 | 200 | A(AC) | ||
| Rated Output | 100 | 100 | mA(AC) | ||
| Ratio | 1000:01:00 | 2000:01:00 | Ratio | ||
| Phase Difference | ≤ 30 ' (RL=20Ω) | ≤ 15 ' (RL=20Ω) | Min | ||
| 0-130 (RL=20Ω) | 0-330 (RL=20Ω) | A(AC) | |||
| Linear Range | 0-130 (RL=50Ω) | 0-300 (RL=50Ω) | A(AC) | ||
| Linearity Degree | 0.50% | 0.50% | % | ||
| DC Resistance | 26±6Ω | 57±8Ω | Ω | ||
| Net weight | 81 | 86 | g | ||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary lead output Note: All parameters are for reference only. For more detailed product information, please feel free to contact us! |
|||||