The suspended‑lead precision current transformer features flexible hanging leads for easy wiring and space‑efficient installation. With a high‑accuracy core and low‑error winding technology, it delivers stable and reliable current measurement over a wide range, making it suitable for laboratory instruments, energy metering, and high‑precision industrial monitoring systems.
| Suspension Lead — Precision Current Transformer | |||||
| ZH-GTA03L Series Precision Current Transformers | |||||
| GTA03L1.0 | GT A03L1.5 | GT A03L2.0 | Unit | ||
| Rated Input | 5 | 15 | 5 | A (AC) | |
| Rated Output | 5 | 10 | 2.5 | mA (AC) | |
| Ratio | 1000:01:00 | 3/2/1900 12:01 | 2000:01:00 | Ratio | |
| Phase Difference | ≤ 15′(RL=20Ω) | ≤ 5′(RL=20Ω) | ≤ 10′(RL=20Ω) | Min | |
| Linear Range | 0-20 (RL=20Ω) | 0-28 (RL=20Ω) | 0-28 (RL=20Ω) | A (AC) | |
| Linear Range | 0-12 (RL=50Ω) | 0-20 (RL=50Ω) | 0-20 (RL=100Ω) | A (AC) | |
| Linearity Degree | 0.20% | 0.10% | 0.10% | % | |
| DC Resistance | 52±5Ω | 86±10Ω | 144±15Ω | Ω | |
| Net weight | 6.4 | 6.6 | 6.7 | g | |
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
| Caution: Current transformers must not be operated in an open-circuit condition and must not be connected to fuses. When using a current transformer, ensure that the load device is connected to the transformer's output terminals first. | |||||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy Resin Installation Method: Primary busbar through-hole, secondary lead output |
|||||
| Suspension Lead — Precision Current Transformer | |||||
| ZH-GTA12L Series Precision Current Transformers | |||||
| GTA08L | Unit | ||||
| Rated Input | 5 | A (AC) | |||
| Rated Output | 5 | mA (AC) | |||
| Ratio | 1000:1 | Ratio | |||
| Phase Difference | ≤15'(RL=20Ω) | Min | |||
| Linear Range | 0-12 (RL=20Ω) | A (AC) | |||
| 0-8 (RL=50Ω) | A (AC) | ||||
| Linearity Degree | 0.002 | % | |||
| DC Resistance | 41±5Ω | Ω | |||
| Net weight | 4.2 | g | |||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
| Caution: Current transformers must not be operated in an open-circuit condition and must not be connected to fuses. When using a current transformer, ensure that the load device is connected to the transformer's output terminals first. | |||||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary lead output |
|||||
| Suspension Lead — Precision Current Transformer | |||||
| ZH-GTA12L Series Precision Current Transformers | |||||
| ZH-GTA12L1.0 | ZH-GTA12L1.5 | Unit | |||
| Rated Input | 20 | 15 | A (AC) | ||
| Rated Output | 20 | 10 | mA (AC) | ||
| Ratio, | 1000:1 | 2000:1 | Ratio | ||
| Phase Difference | ≤ 15′(RL=20Ω) | ≤ 5′(RL=20Ω) | Min | ||
| Linear Range | 0-40 (RL=40Ω) | 0-90 (RL=20Ω) | A (AC) | ||
| Linear Range | 0-25 (RL=50Ω) | 0-70 (RL=50Ω) | A (AC) | ||
| Linearity Degree | 0.2% | 0.1% | % | ||
| DC Resistance | 52±8Ω | 90±10Ω | Ω | ||
| Net weight | 10.6 | 11.2 | g | ||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
| Caution: Current transformers must not be operated in an open-circuit condition and must not be connected to fuses. When using a current transformer, ensure that the load device is connected to the transformer's output terminals first. | |||||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy Resin Installation Method: Primary busbar through-hole, secondary pin output |
|||||
| Suspension Lead — Precision Current Transformer | |||||
| ZH-GTA06L Series Precision Current Transformers | |||||
| ZH-GTA06L1.0 | ZH-GTA06L2.0 | Unit | |||
| Rated Input | 10 | 20 | A (AC) | ||
| Rated Output | 10 | 10 | mA (AC) | ||
| Ratio, | 1000:1 | 2000:1 | Ratio | ||
| Phase Difference | ≤ 10′(RL=20Ω) | ≤ 5′(RL=20Ω) | Min | ||
| Linear Range | 0-30 (RL=20Ω) | 0-80 (RL=20Ω) | A (AC) | ||
| Linear Range | 0-20 (RL=50Ω) | 0-60 (RL=50Ω) | A (AC) | ||
| Linearity Degree | 0.2% | 0.1% | % | ||
| DC Resistance | 36±5Ω | 102±15Ω | Ω | ||
| Net weight | 10.8 | 11.2 | g | ||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
| Caution: Current transformers must not be operated in an open-circuit condition and must not be connected to fuses. When using a current transformer, ensure that the load device is connected to the transformer's output terminals first. | |||||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy Resin Installation Method: Primary busbar through-hole, secondary lead output |
|||||
| Suspension Lead — Precision Current Transformer | |||||
| ZH-GTA20L Series Precision Current Transformers | |||||
| ZH-GTA20L1.0 | ZH-GTA20L1.5 | ZH-GTA20L2.0 | Unit | ||
| Rated Input | 20 | 30 | 40 | A (AC) | |
| Rated Output | 20 | 20 | 20 | mA (AC) | |
| Ratio, | 1000:1 | 1500:1 | 2000:1 | Ratio | |
| Phase Difference | ≤ 5′(RL=20Ω) | ≤ 5′(RL=20Ω) | ≤ 5′(RL=20Ω) | Min | |
| Linear Range | 0-60 (RL=20Ω) | 0-60 (RL=20Ω) | 0-80 (RL=20Ω) | A (AC) | |
| Linear Range | 0-40 (RL=50Ω) | 0-40 (RL=50Ω) | 0-70 (RL=50Ω) | A (AC) | |
| Linearity Degree | 0.1% | 0.1% | 0.1% | % | |
| DC Resistance | 32±6Ω | 65±10Ω | 122±15Ω | Ω | |
| Net weight | 17.6 | 11.2 | 17.3 | g | |
| Dimension Tolerance | 0.5 | mm | |||
| Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | ||||
| Caution: Current transformers must not be operated in an open-circuit condition and must not be connected to fuses. When using a current transformer, ensure that the load device is connected to the transformer's output terminals first. | |||||
| ZH-GTA20L2.5 Series Precision Current Transformers | |||||
| ZH-GTA20L2.5 | ZH-GTA20L3.0 | ZH-GTA20L4.0 | Unit | ||
| Rated Input | 50 | 60 | 80 | A (AC) | |
| Rated Output | 20 | 20 | 20 | mA (AC) | |
| Ratio, | 2500:1 | 3000:1 | 4000:1 | Ratio | |
| Phase Difference | ≤ 5′(RL=20Ω) | ≤ 5′(RL=20Ω) | ≤ 5′(RL=20Ω) | Min | |
| Linear Range | 0-90 (RL=20Ω) | 0-110 (RL=20Ω) | 0-130 (RL=20Ω) | A (AC) | |
| Linear Range | 0-80 (RL=50Ω) | 0-90 (RL=50Ω) | 0-120 (RL=50Ω) | A (AC) | |
| Linearity Degree | 0.1% | 0.1% | 0.1% | % | |
| DC Resistance | 160±20Ω | 187±20Ω | 314±30Ω | Ω | |
| Net weight | 18.8 | 18.8 | 19.2 | g | |
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
| Caution: Current transformers must not be operated in an open-circuit condition and must not be connected to fuses. When using a current transformer, ensure that the load device is connected to the transformer's output terminals first. | |||||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary lead output |
|||||
| Suspension Lead — Precision Current Transformer | |||||
| ZH-GTA07L Series Precision Current Transformers | |||||
| GTA07L1.0 | GTA07L2.0 | Unit | |||
| Rated Input | 20 | 50 | A(AC) | ||
| Rated Output | 20 | 25 | mA(AC) | ||
| Ratio | 1000:01:00 | 2000:01:00 | Ratio | ||
| Phase Difference | ≤5 ' (RL=20Ω) | ≤5 ' (RL=20Ω) | Min | ||
| 0-50 (RL=20Ω) | 0-110 (RL=20Ω) | A(AC) | |||
| Linear Range | 0-32 (RL=50Ω) | 0-90 (RL=50Ω) | A(AC) | ||
| Linearity Degree | 0.10% | 0.10% | % | ||
| DC Resistance | 44±6Ω | 112±15Ω | Ω | ||
| Net weight | 15.9 | 18 | g | ||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy Resin Installation Method: Primary busbar through-hole, secondary lead output |
|||||
| Suspension Lead — Precision Current Transformer | |||||
| ZH-GTA25L Series Precision Current Transformers | |||||
| GTA25L2.0 | Unit | ||||
| Rated Input | 100 | A(AC) | |||
| Rated Output | 50 | mA(AC) | |||
| Ratio | 83.3340277778 | Ratio | |||
| Phase Difference | ≤5 ' (RL=20Ω) | Min | |||
| Linear Range | 0-200 (RL=20Ω) | A(AC) | |||
| 0-180 (RL=50Ω) | A(AC) | ||||
| Linearity Degree | 0.001 | % | |||
| DC Resistance | 68±10Ω | Ω | |||
| Net weight | 29.4 | g | |||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardancy: Complies with UL94-V0 Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary lead output |
|||||
| Suspension Lead — Precision Current Transformer | |||||
| ZH-GD-01Series Precision Current Transformers | |||||
| GD-01A1.5 | GD-01A2.0 | Unit | |||
| Rated Input | 15 | 40 | A(AC) | ||
| Rated Output | 10 | 20 | mA(AC) | ||
| Ratio | 1500:01:00 | 2000:01:00 | Ratio | ||
| Phase Difference | ≤5 ' (RL=20Ω) | ≤5 ' (RL=20Ω) | Min | ||
| Linear Range | 0-50 (RL=20Ω) | 0-70 (RL=20Ω) | A(AC) | ||
| 0-40 (RL=50Ω) | 0-50 (RL=50Ω) | A(AC) | |||
| Linearity Degree | 0.10% | 0.10% | % | ||
| DC Resistance | 63±10Ω | 108±15Ω | Ω | ||
| Net weight | 12.4 | 12.1 | g | ||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary lead output |
|||||
| Suspension Lead — Precision Current Transformer | |||||
| ZH-GTA20L Series Precision Current Transformers | |||||
| GTA23L1.0 | GTA23L2.0 | GTA23L2.5 | Unit | ||
| Rated Input | 50 | 30 | 50 | A(AC) | |
| Rated Output | 50 | 15 | 20 | mA(AC) | |
| Ratio | 1000:01:00 | 2000:01:00 | 2500:01:00 | Ratio | |
| Phase Difference | ≤5 ' (RL=20Ω) | ≤5 ' (RL=20Ω) | ≤5 ' (RL=20Ω) | Min | |
| Linear Range | 0-70 (RL=20Ω) | 0-120 (RL=20Ω) | 0-110 (RL=20Ω) | A(AC) | |
| 0-60 (RL=50Ω) | 0-90 (RL=50Ω) | 0-100 (RL=50Ω) | A(AC) | ||
| Linearity Degree | 0.10% | 0.10% | 0.10% | % | |
| DC Resistance | 33±6Ω | 86±10Ω | 111±15Ω | Ω | |
| Net weight | 18.4 | 19.9 | 20.2 | g | |
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary lead output |
|||||
| Suspension Lead — Precision Current Transformer | |||||
| ZH-GTA34LSeries Precision Current Transformers | |||||
| GTA23L1.0 | GTA23L2.0 | GTA23L2.5 | Unit | ||
| Rated Input | 50 | 30 | 50 | A(AC) | |
| Rated Output | 50 | 15 | 20 | mA(AC) | |
| Ratio | 1000:01:00 | 2000:01:00 | 2500:01:00 | Ratio | |
| Phase Difference | ≤5 ' (RL=20Ω) | ≤5 ' (RL=20Ω) | ≤5 ' (RL=20Ω) | Min | |
| Linear Range | 0-70 (RL=20Ω) | 0-120 (RL=20Ω) | 0-110 (RL=20Ω) | A(AC) | |
| 0-60 (RL=50Ω) | 0-90 (RL=50Ω) | 0-100 (RL=50Ω) | A(AC) | ||
| Linearity Degree | 0.10% | 0.10% | 0.10% | % | |
| DC Resistance | 33±6Ω | 86±10Ω | 111±15Ω | Ω | |
| Net weight | 18.4 | 19.9 | 20.2 | g | |
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary lead output |
|||||
| Suspension Lead — Precision Current Transformer | |||||
| ZH-GTA15LSeries Precision Current Transformers | |||||
| GTA15L2.0 | Unit | ||||
| Rated Input | 100 | A(AC) | |||
| Rated Output | 50 | mA(AC) | |||
| Ratio | 83.3340277778 | Ratio | |||
| Phase Difference | ≤ 30 ' (RL=10Ω) | Min | |||
| Linear Range | 0-600 (RL=10Ω) | A(AC) | |||
| Linearity Degree | 0.005 | % | |||
| DC Resistance | 72±10Ω | Ω | |||
| Net weight | 63 | g | |||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary lead output |
|||||
| Suspension Lead — Precision Current Transformer | |||||
| ZH-GTA01LSeries Precision Current Transformers | |||||
| Type | GTA01L1.0 | GTA01L1.5 | GTA01L2.0 | Unit | |
| Rated Input | 25 | 60 | 50 | A(AC) | |
| Rated Output | 25 | 40 | 25 | mA(AC) | |
| Ratio | 1000:01:00 | 1500:01:00 | 2000:01:00 | Ratio | |
| Phase Difference | ≤5 ' (RL=20Ω) | ≤5 ' (RL=20Ω) | ≤5 ' (RL=20Ω) | Min | |
| Linear Range | 0-55 (RL=20Ω) | 0-100 (RL=20Ω) | 0-120 (RL=20Ω) | A(AC) | |
| 0-40 (RL=50Ω) | 0-80 (RL=50Ω) | 0-100 (RL=50Ω) | A(AC) | ||
| Linearity Degree | 0.10% | 0.10% | 0.10% | % | |
| DC Resistance | 47±6Ω | 74±10Ω | 98±15Ω | Ω | |
| Net weight | 23.6 | 25.9 | 26.4 | g | |
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
| ZH-GTA01LSeries Precision Current Transformers | |||||
| Type | GTA01L1.0 | GTA01L1.5 | GTA01L2.0 | Unit | |
| Rated Input | 25 | 60 | 50 | A(AC) | |
| Rated Output | 25 | 40 | 25 | mA(AC) | |
| Ratio | 1000:01:00 | 1500:01:00 | 2000:01:00 | Ratio | |
| Phase Difference | ≤5 ' (RL=20Ω) | ≤5 ' (RL=20Ω) | ≤5 ' (RL=20Ω) | Min | |
| Linear Range | 0-55 (RL=20Ω) | 0-100 (RL=20Ω) | 0-120 (RL=20Ω) | A(AC) | |
| 0-40 (RL=50Ω) | 0-80 (RL=50Ω) | 0-100 (RL=50Ω) | A(AC) | ||
| Linearity Degree | 0.10% | 0.10% | 0.10% | % | |
| DC Resistance | 47±6Ω | 74±10Ω | 98±15Ω | Ω | |
| Net weight | 23.6 | 25.9 | 26.4 | g | |
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary lead output |
|||||
| Suspension Lead — Precision Current Transformer | |||||
| ZH-GD-02BSeries Precision Current Transformers | |||||
| GD-02B1.0 | GD-02B2.0 | GD-02B2.5 | Unit | ||
| Rated Input | 50 | 50 | 100 | A(AC) | |
| Rated Output | 50 | 25 | 40 | mA(AC) | |
| Ratio | 1000:01:00 | 2000:01:00 | 2500:01:00 | Ratio | |
| Phase Difference | ≤ 10 ' (RL=20Ω) | ≤ 10 ' (RL=20Ω) | ≤5 ' (RL=20Ω) | Min | |
| Linear Range | 0-60 (RL=20Ω) | 0-120 (RL=20Ω) | 0-150 (RL=20Ω) | A(AC) | |
| Linearity Degree | 0.10% | 0.10% | 0.10% | % | |
| DC Resistance | 35±6Ω | 117±20Ω | 83±15Ω | Ω | |
| Net weight | 22.5 | 22.3 | / | g | |
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000MS at normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary lead output' |
|||||
| Suspension Lead — Precision Current Transformer | |||||
| ZH-GTA26LSeries Precision Current Transformers |
|||||
| GTA26L2.0 | Unit | ||||
| Rated Input | 200 | A(AC) | |||
| Rated Output | 100 | mA(AC) | |||
| Ratio | 83.3340277778 | Ratio | |||
| Phase Difference | ≤ 30 ' (RL=20Ω) | Min | |||
| Linear Range | 0-240 (RL=20Ω) | A(AC) | |||
| 0-200 (RL=50Ω) | A(AC) | ||||
| Linearity Degree | 0.005 | % | |||
| DC Resistance | 60±10Ω | Ω | |||
| Net weight | 66.1 | g | |||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000MS at normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary lead output' |
|||||
| Suspension Lead — Precision Current Transformer | |||||
| ZH-GTA29LSeries Precision Current Transformers | |||||
| GTA29L1.0 | GTA29L2.0 | Unit | |||
| Rated Input | 100 | 100 | A(AC) | ||
| Rated Output | 100 | 50 | mA(AC) | ||
| Ratio | 1000:01:00 | 2000:01:00 | Ratio | ||
| Phase Difference | ≤ 70 ' (RL=20Ω) | ≤ 35 ' (RL=20Ω) | Min | ||
| Linear Range | 0-120 (RL=20Ω) | 0-150 (RL=20Ω) | A(AC) | ||
| Linearity Degree | 0.50% | 0.50% | % | ||
| DC Resistance | 25±5Ω | 107±15Ω | Ω | ||
| Net weight | 27 | 26.2 | g | ||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000 MΩ under normal conditions Voltage Rating: 0.66/0.72 kV Withstand Voltage: 4 kV/50 Hz/1 min Operating Frequency: 50/60 Hz Operating Temperature: -40°C to +70°C Sealing Material: Epoxy Resin Installation Method: Primary busbar through-hole, secondary lead output |
|||||
| Suspension Lead — Precision Current Transformer | |||||
| ZH-GTA11LSeries Precision Current Transformers | |||||
| GTA11L3.0 | GTA11L4.0 | Unit | |||
| Rated Input | 100 | 100 | A(AC) | ||
| Rated Output | 33.3 | 25 | mA(AC) | ||
| Ratio | 3000:01:00 | 4000:01:00 | Ratio | ||
| Phase Difference | ≤5 ' (RL=20Ω) | ≤5 ' (RL=20Ω) | Min | ||
| Linear Range | 0-120 (RL=20Ω) | 0-150 (RL=20Ω) | A(AC) | ||
| 0-120 (RL=50Ω) | 0-150 (RL=50Ω) | A(AC) | |||
| Linearity Degree | 0.10% | 0.10% | % | ||
| DC Resistance | 255±30Ω | 410±40Ω | Ω | ||
| Net weight | 44.7 | 45 | g | ||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary lead output |
|||||
| Suspension Lead — Precision Current Transformer | |||||
| ZH-GD-02ASeries Precision Current Transformers | |||||
| GD-02A1.0 | GD-02A2.0 | Unit | |||
| Rated Input | 100 | 100 | A(AC) | ||
| Rated Output | 100 | 50 | mA(AC) | ||
| Ratio | 1000:01:00 | 2000:01:00 | Ratio | ||
| Phase Difference | ≤ 30 ' (RL=20Ω) | ≤ 30 ' (RL=20Ω) | Min | ||
| Linear Range | 0-150 (RL=20Ω) | 0-200 (RL=20Ω) | A(AC) | ||
| 0-90 (RL=50Ω) | 0-200 (RL=50Ω) | A(AC) | |||
| Linearity Degree | 0.50% | 0.50% | % | ||
| DC Resistance | 19±5Ω | 69±10Ω | Ω | ||
| Net weight | 20.6 | 20.6 | g | ||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000 MΩ under normal conditions Voltage Rating: 0.66/0.72 kV Withstand Voltage: 4 kV/50 Hz/1 min Operating Frequency: 50/60 Hz Operating Temperature: -40°C to +70°C Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary lead output |
|||||
| Suspension Lead — Precision Current Transformer | |||||
| ZH-CT-20Series Precision Current Transformers | |||||
| CT-20A1.0 | CT-20A2.0 | Unit | |||
| Rated Input | 100 | 200 | A(AC) | ||
| Rated Output | 100 | 100 | mA(AC) | ||
| Ratio | 1000:01:00 | 2000:01:00 | Ratio | ||
| Phase Difference | ≤ 30 ' (RL=10Ω) | ≤ 30 ' (RL=10Ω) | Min | ||
| Linear Range | 0-300 (RL=10Ω) | 0-1000 (RL=10Ω) | A(AC) | ||
| Linearity Degree | 0.50% | 0.50% | % | ||
| DC Resistance | 30±5Ω | 66±10Ω | Ω | ||
| Net weight | 57 | 63 | g | ||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000 MΩ under normal conditions Voltage Rating: 0.66/0.72 kV Withstand Voltage: 4 kV/50 Hz/1 min Operating Frequency: 50/60 Hz Operating Temperature: -40°C to +70°C Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary lead output |
|||||
| Suspension Lead — Precision Current Transformer | |||||
| ZH-CT-23Series Precision Current Transformers | |||||
| CT-23A2.0 | CT-23A2.0 | Unit | |||
| Rated Input | 200 | 250 | A(AC) | ||
| Rated Output | 100 | 125 | mA(AC) | ||
| Ratio | 2000:01:00 | 2000:01:00 | Ratio | ||
| Phase Difference | ≤ 30 ' (RL=10Ω) | ≤ 30 ' (RL=10Ω) | Min | ||
| Linear Range | 0-1000 (RL=10Ω) | 0-1200 (RL=10Ω) | A(AC) | ||
| Linearity Degree | 0.50% | 0.50% | % | ||
| DC Resistance | 72±10Ω | 54±6Ω | Ω | ||
| Net weight | 68 | 78 | g | ||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000 MΩ under normal conditions Voltage Rating: 0.66/0.72 kV Withstand Voltage: 4 kV/50 Hz/1 min Operating Frequency: 50/60 Hz Operating Temperature: -40°C to +70°C Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary lead output |
|||||
| Suspension Lead — Precision Current Transformer | |||||
| ZH-GTA31LSeries Precision Current Transformers | |||||
| GTA31L3.0 | GTA31L4.0 | Unit | |||
| Rated Input | 300 | 400 | A(AC) | ||
| Rated Output | 100 | 100 | mA(AC) | ||
| Ratio | 3000:01:00 | 4000:01:00 | Ratio | ||
| Phase Difference | ≤ 15 ' (RL=10Ω) | ≤ 15 ' (RL=10Ω) | Min | ||
| Linear Range | 0-1800 (RL=10Ω) | 0-2400 (RL=10Ω) | A(AC) | ||
| Linearity Degree | 0.50% | 0.50% | % | ||
| DC Resistance | 82±10Ω | 116±15Ω | Ω | ||
| Net weight | 70.8 | 72.1 | g | ||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary lead output |
|||||
| Suspension Lead — Precision Current Transformer | |||||
| ZH-CT-32Series Precision Current Transformers | |||||
| CT-32A3.0 | CT-32A4.0 | CT-32A5.0 | Unit | ||
| Rated Input | 300 | 400 | 500 | A(AC) | |
| Rated Output | 100 | 100 | 100 | mA(AC) | |
| Ratio | 3000:01:00 | 4000:01:00 | 5000:01:00 | Ratio | |
| Phase Difference | ≤ 30 ' (RL=10Ω) | ≤ 30 ' (RL=10Ω) | ≤ 30 ' (RL=10Ω) | Min | |
| Linear Range | 0-1800 (RL=10Ω) | 0-2400 (RL=10Ω) | 0-3000 (RL=10Ω) | A(AC) | |
| Linearity Degree | 0.50% | 0.50% | 0.50% | % | |
| DC Resistance | 95±15Ω | 120±20Ω | 140±15Ω | Ω | |
| Net weight | 100 | 108 | 115 | g | |
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000MS at normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary lead output |
|||||
| Suspension Lead — Precision Current Transformer | |||||
| ZH-CT-43Series Precision Current Transformers | |||||
| CT-43A5.0 | CT-43A6.0 | CT-43A8.0 | Unit | ||
| Rated Input | 500 | 600 | 800 | A(AC) | |
| Rated Output | 100 | 100 | 100 | mA(AC) | |
| Ratio | 5000:01:00 | 6000:01:00 | 8000:01:00 | Ratio | |
| Phase Difference | ≤ 30 ' (RL=10Ω) | ≤ 30 ' (RL=10Ω) | ≤ 30 ' (RL=10Ω) | Min | |
| Linear Range | 0-2500 (RL=10Ω) | 0-3000 (RL=10Ω) | 0-4000 (RL=10Ω) | A(AC) | |
| Linearity Degree | 0.50% | 0.50% | 0.50% | % | |
| DC Resistance | 135±20Ω | 167±20Ω | 232±25Ω | Ω | |
| Net weight | 153.4 | 162.3 | 168.2 | g | |
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary lead output |
|||||
| Suspension Lead — Precision Current Transformer | |||||
| ZH-GTA37LSeries Precision Current Transformers |
|||||
| GTA37L2.0 | Unit | ||||
| Rated Input | 50 | A(AC) | |||
| Rated Output | 25 | mA(AC) | |||
| Ratio | 83.3340277778 | Ratio | |||
| Phase Difference | ≤ 10 ' (RL=5Ω) | Min | |||
| Linear Range | 0-70 (RL=5Ω) | A(AC) | |||
| Linearity Degree | 0.001 | % | |||
| DC Resistance | 80±15Ω | Ω | |||
| Net weight | 5.7 | g | |||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000 MΩ under normal conditions Voltage Rating: 0.66/0.72 kV Withstand Voltage: 4 kV/50 Hz/1 min Operating Frequency: 50/60 Hz Operating Temperature: -40°C to +70°C Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary lead output |
|||||
| Suspension Lead — Precision Current Transformer | |||||
| ZH-GTA36LSeries Precision Current Transformers |
|||||
| GTA36L1.5 | Unit | ||||
| Rated Input | 60 | A(AC) | |||
| Rated Output | 40 | mA(AC) | |||
| Ratio | 62.5006944444 | Ratio | |||
| Phase Difference | ≤5 ' (RL=5Ω) | Min | |||
| Linear Range | 0-72 (RL=5Ω) | A(AC) | |||
| Linearity Degree | 0.001 | % | |||
| DC Resistance | 60±10Ω | Ω | |||
| Net weight | 8 | g | |||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-VO Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy Resin Installation Method: Primary busbar through-hole, secondary lead output Note: All parameters are for reference only. For more detailed product information, please feel free to contact us! |
|||||