The horizontal pin‑type precision current transformer features pins parallel to the mounting surface, enabling low‑profile, high‑density installation. With high‑accuracy measurement and excellent temperature stability, it is ideal for compact energy monitoring modules, industrial control boards, and space‑constrained embedded systems.
| Horizontal Pin-Type — Precision Current Transformer | |||||
| ZH-GTA16ZASeries Precision Current Transformers | |||||
| GTA16ZA1.0 | GTA16ZA2.0 | Unit | |||
| Rated Input | 5 | 20 | A(AC) | ||
| Rated Output | 5 | 10 | mA(AC) | ||
| Ratio | 1000:01:00 | 2000:01:00 | Ratio | ||
| Phase Difference | ≤ 15 ' (RL=20Ω) | ≤5 ' (RL=20Ω) | Min | ||
| Linear Range | 0-20 (RL=20Ω) | 0-50 (RL=20Ω) | A(AC) | ||
| 0-15 (RL=50Ω) | 0-40 (RL=50Ω) | A(AC) | |||
| Linearity Degree | 0.20% | 0.10% | % | ||
| DC Resistance | 55±6Ω | 144±15Ω | Ω | ||
| Net weight | 6.2 | 8.4 | g | ||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | ||||
|
|||||
| Flame Retardant Properties: Complies with UL94-VO Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary pin output |
|||||
| Horizontal Pin-Type — Precision Current Transformer | |||||
| ZH-GL-CT104F Series Precision Current Transformers | |||||
| GL-CT104F1.0 | GL-CT104F2.0 | Unit | |||
| Rated Input | 5 | 5 | A(AC) | ||
| Rated Output | 5 | 2.5 | mA(AC) | ||
| Ratio | 1000:01:00 | 2000:01:00 | Ratio | ||
| Phase Difference | ≤ 10 ' (RL=20Ω) | ≤ 10 ' (RL=20Ω) | Min | ||
| Linear Range | 0-20 (RL=20Ω) | 0-40 (RL=20Ω) | A(AC) | ||
| 0-15 (RL=50Ω) | 0-26 (RL=100Ω) | A(AC) | |||
| Linearity Degree | 0.20% | 0.10% | % | ||
| DC Resistance | 67±10Ω | 155±15Ω | Ω | ||
| Net weight | 6.3 | 6.8 | g | ||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-VO Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy Resin Installation Method: Primary busbar through-hole, secondary pin output |
|||||
| Horizontal Pin-Type — Precision Current Transformer | |||||
| ZH-GTA04Z Series Precision Current Transformers | |||||
| GTA04Z1.0 | GTA04Z2.0 | Unit | |||
| Rated Input | 5 | 5 | A(AC) | ||
| Rated Output | 5 | 2.5 | mA(AC) | ||
| Ratio | 1000:01:00 | 2000:01:00 | Ratio | ||
| Phase Difference | ≤ 15 ' (RL=20Ω) | ≤ 15 ' (RL=20Ω) | Min | ||
| Linear Range | 0-20 (RL=0Ω) | 0-20 (RL=0Ω) | A(AC) | ||
| 0-12 (RL=20Ω) | 0-15 (RL=20Ω) | A(AC) | |||
| Linearity Degree | 0.20% | 0.10% | % | ||
| DC Resistance | 40±5Ω | 139±15Ω | Ω | ||
| Net weight | 3.5 | 3.7 | g | ||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary pin output |
|||||
| Horizontal Pin-Type — Precision Current Transformer | |||||
| ZH-GL-CT103F Series Precision Current Transformers | |||||
| GL-CT103F1.0 | GL-CT103F2.0 | Unit | |||
| Rated Input | 20 | 20 | A(AC) | ||
| Rated Output | 20 | 10 | mA(AC) | ||
| Ratio | 1000:01:00 | 2000:01:00 | Ratio | ||
| Phase Difference | ≤ 10 ' (RL=20Ω) | ≤5 ' (RL=20Ω) | Min | ||
| Linear Range | 0-24 (RL=20Ω) | 0-40 (RL=20Ω) | A(AC) | ||
| Linearity Degree | 0.20% | 0.10% | % | ||
| DC Resistance | 48±10Ω | 144±15Ω | Ω | ||
| Net weight | 4.6 | 4.7 | g | ||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary pin output |
|||||
| Horizontal Pin-Type — Precision Current Transformer | |||||
| ZH-GL-030P Series Precision Current Transformers | |||||
| GL-030P | Unit | ||||
| Rated Input | 10 | A(AC) | |||
| Rated Output | 10 | mA(AC) | |||
| Ratio | 41.6673611111 | Ratio | |||
| Phase Difference | ≤5 ' (RL=20Ω) | Min | |||
| 0-15 (RL=20Ω) | A(AC) | ||||
| Linear Range | 0-10 (RL=50Ω) | A(AC) | |||
| Linearity Degree | 0.002 | % | |||
| DC Resistance | 41±5Ω | Ω | |||
| Net weight | 4 | g | |||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | ||||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary pin output |
|||||
| Horizontal Pin-Type — Precision Current Transformer | |||||
| ZH-GTA02ZWSeries Precision Current Transformers |
|||||
| GTA02ZW1.0 | GTA02ZW2.0 | Unit | |||
| Rated Input | 10 | 30 | A(AC) | ||
| Rated Output | 10 | 15 | mA(AC) | ||
| Ratio | 1000:01:00 | 2000:01:00 | Ratio | ||
| Phase Difference | ≤5 ' (RL=20Ω) | ≤5 ' (RL=20Ω) | Min | ||
| Linear Range | 0-30 (RL=20Ω) | 0-50 (RL=20Ω) | A(AC) | ||
| 0-20 (RL=50Ω) | 0-40 (RL=50Ω) | A(AC) | |||
| Linearity Degree | 0.20% | 0.10% | % | ||
| DC Resistance | 45±8Ω | 144±15Ω | Ω | ||
| Net weight | 7.8 | 8 | g | ||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary pin output |
|||||
| Horizontal Pin-Type — Precision Current Transformer | |||||
| ZH-GTA14ZBWSeries Precision Current Transformers |
|||||
| GTA14ZBW1.0 | GTA14ZBW2.0 | Unit | |||
| Rated Input | 20 | 40 | A(AC) | ||
| Rated Output | 20 | 20 | mA(AC) | ||
| Ratio | 1000:01:00 | 2000:01:00 | Ratio | ||
| Phase Difference | ≤5 ' (RL=20Ω) | ≤5 ' (RL=20Ω) | Min | ||
| Linear Range | 0-60 (RL=20Ω) | 0-70 (RL=20Ω) | A(AC) | ||
| 0-40 (RL=50Ω) | 0-50 (RL=50Ω) | A(AC) | |||
| Linearity Degree | 0.10% | 0.10% | % | ||
| DC Resistance | 31±5Ω | 100±15Ω | Ω | ||
| Net weight | 13.7 | 13 | g | ||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | / | |||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary pin output |
|||||
| Horizontal Pin-Type — Precision Current Transformer | |||||
| ZH-GTA05ZWSeries Precision Current Transformers |
|||||
| GTA05ZW1.0 | GTA05ZW2.0 | Unit | |||
| Rated Input | 25 | 50 | A(AC) | ||
| Rated Output | 25 | 25 | mA(AC) | ||
| Ratio | 1000:01:00 | 2000:01:00 | Ratio | ||
| Phase Difference | ≤5 ' (RL=20Ω) | ≤5 ' (RL=20Ω) | Min | ||
| 0-50 (RL=20Ω) | 0-110 (RL=20Ω) | A(AC) | |||
| Linear Range | 0-32 (RL=50Ω) | 0-90 (RL=50Ω) | A(AC) | ||
| Linearity Degree | 0.10% | 0.10% | % | ||
| DC Resistance | 44±6Ω | 112±15Ω | Ω | ||
| Net weight | 14.8 | 17 | g | ||
| Dimension Tolerance | 0.5 | mm | |||
| Application | Primary current flows into the transformer from P1, while secondary winding current flows into the external circuit from S1. | ||||
|
|||||
| Flame Retardant Properties: Complies with UL94-V0 Insulation Resistance: Greater than 1000MΩ under normal conditions Voltage Rating: 0.66/0.72KV Withstand Voltage: 4KV/50Hz/1min Operating Frequency: 50/60Hz Operating Temperature: -40℃ to +70℃ Sealing Material: Epoxy resin Installation Method: Primary busbar through-hole, secondary pin output |
|||||